<LOGO>
FM Transmitter Measurement Report
Created: 2023-05-23 08-55-06
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.50 MHz 5/5, 78 dBuV RIRE &
Pilot RDS Phase Difference
7.0 kHz 3.6 kHz 53 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
8 kHz 64 kHz 16949 0,1416
Modulation Power
Limit Measuring Tolerance
9,0 dBr 0,0 dBr
MIN AVE MAX % above 9,0 dBr
5,8 dBr 6,79 dBr 7,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RIRE & " F226 0 (No PTY) 1 0 1 2 --:--
RT
"RIRE : L "
AF EON
87.8, 88.7, 94.4, 95.4, 95.5, 96.2, 101.5 MHz -
FM Scope Station: 101.50 MHz, signal: 5/5 (78 dBuV) Max at: 64 kHz MIN: 8 kHz % above 75 kHz: 0,1416 Acquired: 2023/05/23 8:54:02 Total samples: 16949 Equivalent time: 0:14:07 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 7,5 dBr MIN: 5,8 dBr AVE: 6,79 dBr % above 9,0 dBr: 0,0 Last value: 6,4 dBr (2023/05/23 8:54:00) Station: 101.50 MHz, signal: 5/5 (78 dBuV) 08:42 08:44 08:46 08:48 08:50 08:52 08:54 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality